Compliance: |
EN50131-1:2006 + A1:2009 Grade 2 and environmental class II, EN50131-3:2009, EN50131-6:2008, BS8243:2010, PD6662:2017 |
Zones: |
30 Radio and 10 wired on board, expandable to 80, all fully programmable |
Partitions: |
4 independent partitions each with a part set or full set and three-part sets |
Users: |
50 user codes, 4 digit PIN number, proximity, remote control or radio panic button |
Wired keypads: |
The ability to add up to four wired keypads |
Event log: |
1000 events; 750 mandatory events and 250 non-mandatory |
Outputs: |
One programmable relay outputs One 500mA open collector programmable outputs 12 low-current outputs for plug-by communicators 10 radio outputs |
Bus Devices: |
Accepts up to 20 bus devices (keypads, expanders and power supplies) |
Internal Sounder: |
One independently controlled 16 Ω speaker 4 internal radio sounders |
External Sirens: |
Dedicated Siren and Strobe open collector outputs 4 External Radio Sirens |
Remote Communications: |
SIA IP via built-in Ethernet port Email and images via built-in Ethernet port Footprint for connection of a range of alarm communications modules as described below |
Visual Verification: |
Up to 4 IP cameras |
Power Supply: |
Conforms to EN50131-6:2008 Type A power supply, rated power output 1.0A. 650mA is available for auxiliary power |
Configurations Options: |
Eaton Downloader via USB, IP or plug-on comms module, web browser via built-in Ethernet port |
Battery: |
Accepts a 12v standby battery up to 7Ah rechargeable lead acid, gel type |
Dimensions: |
End station: 384 x 245 x 94mm |
Weight: |
End station: 2.2kg |
Temperature Range: |
Environmental class II. Tested -10°C to 55°C @ 93% RH |