Firmware
|
V2.x
|
Programmable areas
|
16
|
Max. number of user codes
|
256
|
Event memory
|
10'000 intrusion events, 10'000 access events
|
Number of on-board zones
|
8
|
Max. number of hardwired zones
|
128
|
Max. number of wireless zones
|
120 (take away wired zones)
|
EOL resistor
|
Dual 4k7 (default), other resistor combinations configurable
|
Max. number of outputs
|
128
|
Number of on-board relays
|
1 strobe (30 VDC / 1 A resistive switching current)
|
Number of on-board open coll.
|
2 internal / external bell, 3 freely programmable (each max. 400 mA resistive switching current, supplied via auxiliary output)
|
Door capacity
|
Max. 16 entry doors or 16 entry/exit doors
|
Number of card reader
|
Max. 32
|
Time function
|
32 calendars (53 weeks, multiple on/off switching patterns for users, areas, inputs, outputs, keypads, doors)
|
Macro language
|
Cause & Effect programming (256 triggers / 128 mapping gates)
|
Number of field devices
|
Max. 48 (16 keypads, 16 door-expanders, 16 input/output expanders)
|
Interfaces
|
2 X-BUS (2 spurs or 1 loop),
2 RS232 (to X-10 or external communication),
1 USB (PC connection),
1 SPC Fast Programmer
|
Tamper contact
|
Front spring tamper, 2 auxiliary tamper contact inputs
|
Mains voltage
|
230 VAC, + 10%/ -15%, 50 Hz
|
Operating current
|
Max. 160 mA at 12 VDC
|
Quiescent current
|
Max. 140 mA at 12 VDC
|
Output voltage
|
11-14 VDC in normal conditions (mains powered and fully charged battery),
|
Auxiliary power (nominal)
|
Max. 750 mA at 12 VDC
|
Battery type
|
YUASA NP17-12FR (17 Ah), not supplied
|
Operating temperature
|
0 ~ +40 °C
|
Colour
|
RAL 9003 (signal white)
|
Weight
|
6.100 kg
|
Dimensions (W x H x D)
|
326 x 415 x 114 mm
|
Housing
|
Hinged metal housing (1.2 mm mild steel)
|
Standard / approval
|
EN50131-1, Grade 3, class II
SE: SFF1014, Larmklass 2
NL: REQ, Grade 2, class 2
BE: INCERT
HU: MABISZ
CZ: ZPTS, NBU, ACR
|