Number of on-board zones
|
8
|
EOL resistor
|
Dual 4k7 (default), other resistor combinations configurable
|
Number of on-board relays
|
2 (single-pole changeover, 30 VDC / max. 1 A resistive switching current)
|
Interfaces
|
X-BUS (in, out, branch)
|
Tamper contact
|
Front spring tamper, back tamper
|
Mains voltage
|
230 VAC, + 10%/ -15%, 50 Hz
|
Operating current
|
Max. 117 mA at 12 VDC (all relays activated)
|
Quiescent current
|
Max. 77 mA at 12 VDC
|
Output voltage
|
11-14 VDC in normal conditions (mains powered and fully charged battery)
|
Auxiliary power (nominal)
|
Max. 1500 mA at 12 VDC (750 mA per output)
|
Battery type
|
YUASA NP17-12FR (17 Ah), not supplied
|
Operating temperature
|
0 ~ +40 °C
|
Colour
|
RAL 9003 (signal white)
|
Weight
|
6.300 kg
|
Dimensions (W x H x D)
|
326 x 415 x 114 mm
|
Housing
|
Hinged metal housing (1.2 mm mild steel)
|
Standard / approval
|
EN50131-1 / EN50131-3 / EN50131-6, Grade 3, Class II
UK: PD6662:2010
BE: INCERT
SE: SFF1014, Larmklass 2
|