Model |
FS-5000E |
Detection system |
Ultraviolet rays detection
(detected wave length 180~260nm) |
Detection area |
Distance: 10m (33ft) max. (7cm flame)
Angle
· Horizontal: approx. 100 degrees (60 degrees downward)
· Vertical: approx. 75 degrees (15 degrees upward)
Adjustment range
· Horizontal 25 degrees by base unit
· Vertical 30 degrees (4 steps) by sensor head |
Sensitivity adjustment |
Sensitivity: H (100%), L (50%) (selectable)
Detection timer: 1sec, 6sec, 15sec, 30sec (selectable) |
Power supply |
10V to 30VDC |
Power consumption |
35mA or less |
Alarm output |
Dry contact relay Form C (NO/NC)
Contact capacity: 30V (AC/DC) 0.5A, (resistance load)
Operation time: the following are selectable
· Detection time + off delay operation approx. 2sec to 1min
· Detection time + off delay operation approx. 5sec to 10min
Output operation: the following are selectable
· Same time as above continuous output
· Same time as above flashing output
Operation mode (day/night function):
· 5 lux night time operation
· ∞ lux day time operation (adjustment volume) |
Alarm memory |
Memory LED blinks for 3min., then lights for 47min. (auto-reset) |
LED |
Operation LED (red): synchronous dry contact relay
Memory LED (yellow): blinks for 3min and then lights |
Wiring |
Reed wiring
Power supply: 2 / dry contact: 3 |
Ambient temperature |
-20°C to +50°C (-4°F to +122°F) |
Installation |
Indoor/outdoor |
Weight |
Approx. 550g (19.3oz) |
Appearance |
Sensor part: PC resin (white)
Bracket: AES resin (white) |
Supplied accessories |
· Tapping screw ∅6 x 30: 4pcs
· Tapping screw ∅4 x 8: 1pc
· Band: 1pc