Obsolete
Alternative Click Here
The M600 is designed for maximum flexibility and can be operated from anywhere in the property via multiple remote keypads, it can also be programmed to monitor different rooms at different times.
Key features
-
PD6662 grade 2, once the standard is agreed
-
Simplified, easy-programmable software
-
Energy efficient, intelligent power supplies
-
868MHz narrow-band radio expansion
-
Programmable zone configurations simplify system takeovers
-
Backward compatibility with Menvier Networker expansion
Specifications
General
|
|
Product name |
M600 |
Security Grade |
PD6662: 2004, EN50131-1:2006, TS50131-3:2003, EN50131-6:1997, Grade 1, or 2. DD243:2004. |
Sales number |
M600KEP |
Product Description |
40 Zone Grade 2 Panel with comms |
|
|
Capacities
|
|
Max zones |
40 |
Zones - on board |
8, CC or FSL |
Zones - on expander(s) |
32 |
Standard wired outputs - on board |
3 |
Communicator outputs: |
8 |
Outputs on expander module(s) |
None |
Setting Levels: |
Full set for each ward |
Partitions: |
4 |
Log capacity (events): |
1000 |
No. Keypads |
16 max |
Internal Clock |
±10 minutes over one year (depending on the accuracy of the mains supply frequency). |
Downloader |
Yes |
Remote Servicing |
None |
|
|
Security
|
|
Access code |
4 or 6 digits |
Number of user codes |
50 |
Code blocking |
Programmable |
Proximity tag differs |
4,294,967,296 |
Back tamper (in addition to lid tamper) |
Separate terminals |
|
|
Physical
|
|
End Station dimensions: |
385(W), 312(H), 95(D) mm |
End Station weight (w/o battery): |
4.9 Kg |
Case material |
1.2mm mild steel |
|
|
Keypad
|
|
Keypad name |
MKP1, MKP2, MKP3 |
|
|
Environmental
|
|
Environmental Grade |
Class II |
Operating temperature |
-10 to 40 C |
Humidity |
0 to 75% RH, non-condensing. |
|
|
Radio
|
|
Expander/Built-in: |
Expander (MRNode) |
|
|
PSTN Communications
|
|
Built in Communicator |
Yes |
Plug on communicator |
No |
Plug-by communicator
(uses screw terminals) |
Yes |
Protocols: |
Fast Format, SIA, SIA II, SIA III, Extended SIA II, Contact ID |
Speech Dialler |
No |
ATS rating |
2 |
Line sharing |
Yes |
REN |
0.2 |
|
|
Power Supply
|
|
EN50131-6 Type |
A |
Mains power supply |
145mA @ 230Vac±10%, 50Hz |
End station psu |
13.65VDC, 1.25A. |
End station consumption |
200mA |
Communicator consumption |
n/a |
Standby Battery |
12VDC, lead-acid |
Max recharge time: |
24 hrs max. for 17AH battery |
Battery charge limit |
750mA |
12V Aux supply (inc LS) |
Depends on attached peripherals |
14V4 supply |
None |
|
|
Data Connections
|
|
RS232 |
No |
USB |
Yes |
Printer |
Yes, three pin serial RS232 |
Ethernet |
None |
ISDN |
None |
GSM |
None |
GPRS |
None |
Engineer keypad port |
Yes |
|
|
Wired Outputs
|
|
Bell trigger |
Switched -ve @500mA |
Strobe trigger |
Switched -ve @500mA |
H/0+ (positive holdoff) |
Yes |
H/0- (negative holdoff) |
Yes |
O/P 1 |
1 voltage-free changeover 1A max @ 24Vac or 24Vdc |
O/P 2 |
Switched -ve @500mA |
O/P 3 |
Switched +ve @500mA |
O/P 4 |
n/a |
O/P 5-8 |
n/a |
LS (loudspeaker) |
16 Ohms |
Communication outputs |
8. Source 5mA in 12V condition, sink 100mA in 0V condition, selectable output sense |
ST (Siren test) |
None |
|
|
Wired Inputs
|
|
TR |
Yes, -ve |
Tellback/Remote reset** |
Yes, 0V applied |
Line Fault input** |
Yes, +12V applied |
Aux Tmp |
Yes |
|
|
Fuses
|
|
Mains |
T315mA 250V 20mm |
Other |
The panel uses fast-acting polyswitch fuses for overcurrent protection: |